Usefull SmartData Units
The formation rules for SmartData Units are available in the EPOS user guide.
Some useful SI units are:
SI Unit | SI Quantity | UNIT | Remarks / Other names |
---|---|---|---|
mol | Amount of Substance | 0x8492492c | |
rad/s | Angular Velocity | 0x84B23924 | |
m² | Area | 0x849a4924 | |
A | Current | 0x84924b24 | Electric Current |
N | Force | 0x8496A924 | |
kg/m³ | Humidity | 0x8486C924 | |
W/m² | Irradiance | 0x84929924 | |
m | Length | 0x84964924 | |
cd | Luminous Intensity | 0x84924925 | |
kg | Mass | 0x8492c924 | |
W | Power | 0x849A9924 | |
Pa | Pressure | 0x848eA924 | |
m/s | Velocity | 0x84963924 | Speed |
W/m² | Sound Intensity | 0x84929924 | |
K | Temperature | 0x84924964 | |
s | Time | 0x84925924 | |
V | Voltage | 0x849a9724 | |
m³ | Volume | 0x849e4924 | |
m³/s | Water Flow | 0x849e3924 | |
- | ratio | 0xF8000000 | not an SI unit |
% | Percentage | 0xF8000001 | not an SI unit |
- | PPM | 0xF8000002 | not an SI unit |
- | PPB | 0xF8000003 | not an SI unit |
- | Relative Humidity | 0xF8000004 | not an SI unit |
- | Power Factor | 0xF8000005 | not an SI unit |
- | Counter | 0xF8000006 | not an SI unit |
Some useful Digital units are:
Class | Type | Subtype | Length | UNIT | Remarks |
---|---|---|---|---|---|
Switch | 0 | 0 | 1 | 0x00000000 | |
RFID32 | 1 | 0 | 4 | 0x00000000 | RFIDs and SmartCartds |
Class | Type | Subtype | Length | UNIT | A/V | Hz | Ch | RTP Reference |
---|---|---|---|---|---|---|---|---|
PCMU | 2 | 0 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
GSM | 2 | 3 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
G723 | 2 | 4 | l | 0x00000000 + l | A | 8000 | 1 | Vineet_Kumar, RFC3551 |
DVI4_8 | 2 | 5 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
DVI4_16 | 2 | 6 | l | 0x00000000 + l | A | 16000 | 1 | RFC3551 |
LPC | 2 | 7 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
PCMA | 2 | 8 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
G722 | 2 | 9 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
L16_2 | 2 | 10 | l | 0x00000000 + l | A | 44100 | 2 | RFC3551 |
L16_1 | 2 | 11 | l | 0x00000000 + l | A | 44100 | 1 | RFC3551 |
QCELP | 2 | 12 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
CN | 2 | 13 | l | 0x00000000 + l | A | 8000 | 1 | RFC3389 |
MPA | 2 | 14 | l | 0x00000000 + l | A | 90000 | RFC3551, RFC2250 | |
G728 | 2 | 15 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
DVI4_11 | 2 | 16 | l | 0x00000000 + l | A | 11025 | 1 | Joseph_Di_Pol |
DVI4_22 | 2 | 17 | l | 0x00000000 + l | A | 22050 | 1 | Joseph_Di_Pol |
G729 | 2 | 18 | l | 0x00000000 + l | A | 8000 | 1 | RFC3551 |
CelB | 2 | 25 | l | 0x00000000 + l | V | 90000 | RFC2029 | |
JPEG | 2 | 26 | l | 0x00000000 + l | V | 90000 | RFC2435 | |
nv | 2 | 28 | l | 0x00000000 + l | V | 90000 | RFC3551 | |
H261 | 2 | 31 | l | 0x00000000 + l | V | 90000 | RFC4587 | |
MPV | 2 | 32 | l | 0x00000000 + l | V | 90000 | RFC2250 | |
MP2T | 2 | 33 | l | 0x00000000 + l | AV | 90000 | RFC2250 | |
H263 | 2 | 34 | l | 0x00000000 + l | V | 90000 | Chunrong_Zhu | |
WAV (FLAC) | 2 | 35 | l | 0x00000000 + l | A | 20000 | WAV - FLAC compressed at server |
The WAV (FLAC) type uses on-the-fly compression/decompression for acoustic data with specific characteristics, as described here.
To generate the code for a personalized unit, fill out the parameters in the fields below, and press Generate to view the SmartData Unit code. As an example, the current values in the fields denote the Acceleration unit (m / s²):
SI | Data type | mod | sr | rad | m | kg | s | A | K | mol | cd | |
Binary: Hexa: Decimal: